Are rapid diagnostic tests more accurate in diagnosis of plasmodium falciparum malaria compared to microscopy at rural health centres?
View/ Open
Date
2010Author
Batwala, Vincent
Magnussen, Pascal
Nuwaha, Fred
Metadata
Show full item recordAbstract
Background: Prompt, accurate diagnosis and treatment with artemisinin combination therapy remains vital to
current malaria control. Blood film microscopy the current standard test for diagnosis of malaria has several
limitations that necessitate field evaluation of alternative diagnostic methods especially in low income countries of
sub-Saharan Africa where malaria is endemic.
Methods: The accuracy of axillary temperature, health centre (HC) microscopy, expert microscopy and a HRP2-
based rapid diagnostic test (Paracheck) was compared in predicting malaria infection using polymerase chain
reaction (PCR) as the gold standard. Three hundred patients with a clinical suspicion of malaria based on fever and
or history of fever from a low and high transmission setting in Uganda were consecutively enrolled and provided
blood samples for all tests. Accuracy of each test was calculated overall with 95% confidence interval and then
adjusted for age-groups and level of transmission intensity using a stratified analysis. The endpoints were:
sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV). This study is registered
with Clinicaltrials.gov, NCT00565071.
Results: Of the 300 patients, 88(29.3%) had fever, 56(18.7%) were positive by HC microscopy, 47(15.7%) by expert
microscopy, 110(36.7%) by Paracheck and 89(29.7%) by PCR. The overall sensitivity >90% was only shown by
Paracheck 91.0% [95%CI: 83.1-96.0]. The sensitivity of expert microscopy was 46%, similar to HC microscopy. The
superior sensitivity of Paracheck compared to microscopy was maintained when data was stratified for transmission
intensity and age. The overall specificity rates were: Paracheck 86.3% [95%CI: 80.9-90.6], HC microscopy 93.4% [95%
CI: 89.1-96.3] and expert microscopy 97.2% [95%CI: 93.9-98.9]. The NPV >90% was shown by Paracheck 95.8% [95%
CI: 91.9-98.2]. The overall PPV was <88% for all methods.
Conclusion: The HRP2-based RDT has shown superior sensitivity compared to microscopy in diagnosis of malaria
and may be more suitable for screening of malaria infection.
Collections
- Research Articles [104]