Show simple item record

dc.contributor.authorDrolet, Adam
dc.contributor.authorMugumya, Thomas
dc.contributor.authorHsu, Shan
dc.contributor.authorIzudi, Jonathan
dc.contributor.authorRuhweza, Martin
dc.contributor.authorMugisha, Emmanuel
dc.contributor.authorBahatungire, Rony
dc.contributor.authorCoffey, Patricia S.
dc.date.accessioned2024-10-18T09:24:16Z
dc.date.available2024-10-18T09:24:16Z
dc.date.issued2024
dc.identifier.citationDrolet, A., Mugumya, T., Hsu, S., Izudi, J., Ruhweza, M., Mugisha, E., ... & Coffey, P. S. (2024). Performance and acceptability of the STREAM Disinfectant Generator for infection prevention and control practices in primary health care facilities in Uganda. Antimicrobial Resistance & Infection Control, 13(1), 77.en_US
dc.identifier.urihttp://ir.must.ac.ug/xmlui/handle/123456789/3900
dc.description.abstractBackground: Effective infection prevention and control programs can positively influence quality of care, increase patient safety, and protect health care providers. Chlorine, a widely used and effective chemical disinfectant, is recommended for infection prevention and control in health care settings. However, lack of consistent chlorine availability limits its use. Electrolytic chlorine generators can address limited chlorine supply and stock outs by enabling onsite production of readily usable, high-quality chlorine cost-effectively. We report the feasibility (i.e., performance, accept ability, chlorine availability, and cost) of the electrolytic STREAM Disinfectant Generator (Aqua Research, New Mexico, USA) device for infection prevention and control in primary health care facilities in Uganda. Methods: We installed STREAM devices in 10 primary health care facilities in central and western Uganda. Commercial chlorine inventory records (stock cards) were reviewed in each facility to calculate average liters of chlorine received and used per month. These values were compared with actual STREAM chlorine production volumes over the study period to determine its impact on chlorine availability. We collected acceptability data from a purposive sample of device users (n = 16), hospital administrators (n = 10), and district health officers (n = 6) who had been directly involved in the operation or supervision of the STREAM device. We descriptively analyzed the acceptability data by user group and evaluated qualitative responses manually using a thematic approach. Cost data were normalized and modeled to determine a break-even and cost-savings analysis across a five-year period (the minimum expected lifespan of the STREAM device). Results: Chlorine was consistently available without any reported stock outs during the evaluation period. STREAM chlorine production resulted in a 36.9 percent cost-savings over a five-year period compared to commercial chlorine. User acceptability of the STREAM device was high among STREAM operators, hospital administrators, and district health officers, with all respondents reporting that STREAM moderately or significantly improved infection prevention and control practices in the health facility. Overall, 88 percent of device users and 100 percent of hospital administrators wished to continue using the STREAM device instead of commercial chlorine products. Conclusion: The STREAM device has demonstrated significant potential to strengthen infection prevention and control practices in health care facilities in Uganda. Based on the preliminary results, the STREAM device should be considered a promising tool for district hospitals and large health centers facing infection prevention and control challenges in Uganda and elsewhere, provided water and electricity are available. Going forward, implementation of the STREAM device could also be considered in smaller health care facilities in Uganda and elsewhere.en_US
dc.description.sponsorshipConrad N. Hilton Foundationen_US
dc.language.isoen_USen_US
dc.publisherAntimicrobial Resistance & Infection Controlen_US
dc.subjectChlorineen_US
dc.subjectEnvironmental hygieneen_US
dc.subjectHealth care facilitiesen_US
dc.subjectInfection prevention and controlen_US
dc.subjectUgandaen_US
dc.subjectWASHen_US
dc.titlePerformance and acceptability of the STREAM Disinfectant Generator for infection prevention and control practices in primary health care facilities in Ugandaen_US
dc.typeArticleen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

  • Research Articles [455]
    These are different research articles about different Scholars

Show simple item record