dc.identifier.citation | Drolet, A., Mugumya, T., Hsu, S., Izudi, J., Ruhweza, M., Mugisha, E., ... & Coffey, P. S. (2024). Performance and acceptability of the STREAM Disinfectant Generator for infection prevention and control practices in primary health care facilities in Uganda. Antimicrobial Resistance & Infection Control, 13(1), 77. | en_US |
dc.identifier.uri | http://ir.must.ac.ug/xmlui/handle/123456789/3900 | |
dc.description.abstract | Background: Effective infection prevention and control programs can positively influence quality of care, increase patient safety, and protect health care providers. Chlorine, a widely used and effective chemical disinfectant, is recommended for infection prevention and control in health care settings. However, lack of consistent chlorine availability limits its use. Electrolytic chlorine generators can address limited chlorine supply and stock outs by enabling onsite production of readily usable, high-quality chlorine cost-effectively. We report the feasibility (i.e., performance, accept ability, chlorine availability, and cost) of the electrolytic STREAM Disinfectant Generator (Aqua Research, New Mexico, USA) device for infection prevention and control in primary health care facilities in Uganda.
Methods: We installed STREAM devices in 10 primary health care facilities in central and western Uganda. Commercial chlorine inventory records (stock cards) were reviewed in each facility to calculate average liters of chlorine received and used per month. These values were compared with actual STREAM chlorine production volumes over the study period to determine its impact on chlorine availability. We collected acceptability data from a purposive sample of device users (n = 16), hospital administrators (n = 10), and district health officers (n = 6) who had been directly involved in the operation or supervision of the STREAM device. We descriptively analyzed the acceptability data by user group and evaluated qualitative responses manually using a thematic approach. Cost data were normalized and modeled to determine a break-even and cost-savings analysis across a five-year period (the minimum expected lifespan of the STREAM device).
Results: Chlorine was consistently available without any reported stock outs during the evaluation period. STREAM chlorine production resulted in a 36.9 percent cost-savings over a five-year period compared to commercial chlorine. User acceptability of the STREAM device was high among STREAM operators, hospital administrators, and district health officers, with all respondents reporting that STREAM moderately or significantly improved infection prevention and control practices in the health facility. Overall, 88 percent of device users and 100 percent of hospital administrators wished to continue using the STREAM device instead of commercial chlorine products.
Conclusion: The STREAM device has demonstrated significant potential to strengthen infection prevention and control practices in health care facilities in Uganda. Based on the preliminary results, the STREAM device should be considered a promising tool for district hospitals and large health centers facing infection prevention and control challenges in Uganda and elsewhere, provided water and electricity are available. Going forward, implementation of the STREAM device could also be considered in smaller health care facilities in Uganda and elsewhere. | en_US |
dc.description.sponsorship | Conrad N. Hilton Foundation | en_US |
dc.language.iso | en_US | en_US |
dc.publisher | Antimicrobial Resistance & Infection Control | en_US |
dc.subject | Chlorine | en_US |
dc.subject | Environmental hygiene | en_US |
dc.subject | Health care facilities | en_US |
dc.subject | Infection prevention and control | en_US |
dc.subject | Uganda | en_US |
dc.subject | WASH | en_US |
dc.title | Performance and acceptability of the STREAM Disinfectant Generator for infection prevention and control practices in primary health care facilities in Uganda | en_US |