Weighted average algorithm adjusted a novel (1+FOPI)-FOPI-TID controller structure for AGC with integration of non-linearities and cyber-attack

dc.contributor.authorMoses Awal
dc.contributor.authorMichael Robson Atim
dc.contributor.authorJimmy Nabende Wanzala
dc.contributor.authorJohnes Obungoloch
dc.contributor.authorMohamed Barakat
dc.date.accessioned2026-02-27T08:20:03Z
dc.date.issued2026
dc.description.abstractThe integration of diverse energy sources and the advent of smart grids have intensified the challenges in load frequency management (LFM). Modern power systems are increasingly vulnerable to inherent nonlinearities, such as generation rate constraints, governor dead bands, boiler dynamics, and communication delays, as well as sophisticated cyber-attacks, which collectively threaten frequency stability and tie-line power balance. To address these challenges, this study proposes a novel cascade controller, designated as (1+FOPI)-FOPI-TID, for robust automatic generation control in hybrid two-area power systems. The controller uniquely combines fractional-order (FO) dynamics with a tilt-integral-derivative stage and is optimized using a green metaheuristic, the weighted average algorithm (WAA). The WAA effectively balances exploration and exploitation to achieve superior parameter tuning. The proposed control architecture processes both area control error (ACE) and frequency deviation (ΔF) signals through dedicated stages, enabling enhanced disturbance rejection and transient response. The system model incorporates a comprehensive set of nonlinearities and evaluates resilience against resonance-based cyber-attacks. Comprehensive simulation studies under both AC and HVDC tie-line configurations demonstrate that the WAA-optimized (1+FOPI)- FOPI-TID controller significantly outperforms existing schemes, including PD-PI, PIFOD-(1+PI), and PIDF(1+FOD). Key performance metrics show a 45.3% reduction in the integral of time weighted absolute error (ITAE) and improvements in settling times of 47.7% for ΔF₁ and 32.8% for ΔF₂. Sensitivity analysis confirms robustness under±25% parameter variations and random load perturbations. During cyber-attacks, the controller maintains the lowest Rate of Change of Frequency (RoCoF), underscoring its dual capability in stabilizing grid dynamics and mitigating cyber-physical threats. These results validate the controller’s potential to enhance operational resilience and reliability in future smart grids.
dc.identifier.citationAwal, M., Atim, M. R., Wanzala, J. N., Obungoloch, J., & Barakat, M. (2026). Weighted average algorithm adjusted a novel (1+ FOPI)-FOPI-TID controller structure for AGC with integration of non-linearities and cyber-attack. Scientific Reports.
dc.identifier.urihttps://ir.must.ac.ug/handle/123456789/4268
dc.language.isoen
dc.publisherScientific Reports
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 United Statesen
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/
dc.subjectAutomatic generation control
dc.subject(1+FOPI)-FOPI-TID controller
dc.subjectWeighted average algorithm
dc.subjectCyber-attack
dc.subjectPower systems nonlinearities
dc.subjectRandom step load
dc.titleWeighted average algorithm adjusted a novel (1+FOPI)-FOPI-TID controller structure for AGC with integration of non-linearities and cyber-attack
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Weighted average algorithm adjusted a novel (1+FOPI)-FOPI-TID controller structure for AGC with integration of non-linearities and cyber-attack.pdf
Size:
5.42 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections