Modeling and simulation of human lung mechanics using single to multi-compartment electrical circuit models
| dc.contributor.author | Wanzala, Jimmy Nabende | |
| dc.contributor.author | Atim, Michael Robson | |
| dc.date.accessioned | 2026-09-28T15:47:14Z | |
| dc.date.issued | 2026 | |
| dc.description.abstract | This study focuses on the development, simulation, and comparative analysis of electrical analog models for representing human respiratory mechanics. The respiratory system was modeled using lumped parameter elec¬trical circuits, where physiological variables such as pressure, airflow, lung compliance, airway resistance, and airway inertance were represented by voltage, current, capacitance, resistance, and inductance, respectively. Four distinct models: single-compartment, two-compartment, three-compartment, and multi-compartment were developed and implemented using MATLAB/Simulink and to investigate their predictive accuracy and com¬putational efficiency under both normal and diseased lung conditions, including asthma, COPD, and ARDS. Performance was evaluated using Root Mean Square Error (RMSE), Mean Absolute Error (MAE), and correla¬tion coefficients by comparing the single-, two-, and three-compartment model outputs against a high-fidelity ten-compartment (𝑁𝑁 𝑁 𝑁𝑁) reference model, rather than against patient or clinical ventilator data. Results indi¬cated that predictive error decreased, and correlation with the reference model increased, monotonically with compartment count (from a correlation coefficient of 0.9990 for the single-compartment model to 1.0000 for the 𝑁𝑁 𝑁 𝑁𝑁 reference model itself); the multi-compartment model’s computational complexity makes it more suitable for offline analysis. A weighted decision matrix was used to compare the single-, two-, and three-compartment models on predictive accuracy, computational speed, clinical applicability, ease of parameter estimation, and model stability. A sensitivity analysis showed that the top-ranked model depends materially on how the qualitative criteria (clinical applicability, parameter estimation ease, stability) are scored: under an illustrative expert-judgment scoring the three-compartment model scored highest, while under a fully formula-derived scoring the two-compartment model scored highest instead, and the single-compartment model became competitive with both under weight assumptions with no built-in preference. The study therefore identifies the two- and three-compartment models as the strongest real-time candidates, with the specific choice between them depending on which criteria a given clinical deployment prioritizes, rather than concluding that a single configuration is unconditionally optimal. | |
| dc.identifier.citation | Wanzala, J. N., & Atim, M. R. (2026). Modeling and simulation of human lung mechanics using single to multi-compartment electrical circuit models. Discover Applied Sciences. | |
| dc.identifier.uri | https://ir.must.ac.ug/handle/123456789/4612 | |
| dc.language.iso | en_US | |
| dc.publisher | Discover Applied Sciences | |
| dc.rights | Attribution-NonCommercial-NoDerivs 3.0 United States | en |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | |
| dc.subject | Respiratory mechanics | |
| dc.subject | Electrical analog models | |
| dc.subject | Lung compliance | |
| dc.subject | Airway resistance | |
| dc.subject | Mechanical ventilation | |
| dc.subject | ICU ventilator support | |
| dc.title | Modeling and simulation of human lung mechanics using single to multi-compartment electrical circuit models | |
| dc.type | Article |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Modeling and simulation of human lung mechanics using single to multi-compartment electrical circuit models..pdf
- Size:
- 3 MB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
Loading...
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: