Multiview Integration for Robust Echocardiographic Embeddings

Loading...
Thumbnail Image

Date

Authors

Tohyama, Takeshi
Ahram,Han
Dukyong, Yoon
Paik, Kenneth
Gow, Brian
Nura, Izath
Leo, Anthony Celi
Kpodonu, Jacques

Journal Title

Journal ISSN

Volume Title

Publisher

JACC: Advances

Abstract

BACKGROUND Although recent artificial intelligence (AI) foundation models have shown superior performance in medical imaging, their high computational demands and reliance on large data sets limit accessibility. These issues are especially pronounced in echocardiography, where integrating complex multiview measurements for individual cases hinders AI development and clinical translation. Vector embedding approaches offer promising solutions by leveraging compact representations in AI applications. OBJECTIVES We aimed to develop a transformer-based multiview encoder that integrates multiple echocardiographic videos into unified vector embedding and uses adversarial learning to reduce reliance on demographic shortcuts. METHODS Using the MIMIC-IV-ECHO (Medical Information Mart for Intensive Care IV–Echocardiography) data set (7,169 studies), we trained a multiview encoder to produce study-level embeddings and evaluated them on 21 binary classification tasks covering echocardiographic measurements and clinical diagnoses. We varied adversarial weights to assess their impact on demographic shortcut reliance and overall performance. RESULTS The multiview encoder raised the mean area under the curve (AUC) across clinical tasks from 0.742 to 0.831 compared with the foundation model embedding (ΔAUC +0.090; 95% CI: 0.078-0.100), with significant gains in 20 of 21 tasks. The embeddings remained robust with a limited number of views (mean ΔAUC +0.071; 95% CI: 0.043-0.113). Adversarial learning reduced sex and race predictability only at strong weights and at substantial cost to clinical performance. CONCLUSIONS The multiview encoder framework integrates multiple echocardiographic views into unified study- level embeddings, enabling substantial diagnostic improvements across diverse cardiac tasks. By producing compact, informative embeddings without requiring extensive computational resources, this approach lowers the cost of building echocardiographic AI on an existing foundation model.

Description

Citation

Han, M. A., Gow, B. B., Celi, M. L. A., & Kpodonu, M. J. (2026). Multiview Integration for Robust Echocardiographic Embeddings: Accessible AI for Clinical Practice. JACC: Advances, 5(12), 103488.

Endorsement

Review

Supplemented By

Referenced By

Creative Commons license

Except where otherwised noted, this item's license is described as Attribution-NonCommercial-NoDerivatives 4.0 International