Show simple item record

dc.contributor.authorRukundo, Hope Alice Mbabazi
dc.contributor.authorTaremwa, Ivan Mugisha
dc.contributor.authorMuwanguzi, Enoch
dc.contributor.authorNdyomubantu, Mark
dc.contributor.authorByarugaba, Frederick
dc.contributor.authorNatukunda, Bernard
dc.date.accessioned2022-03-02T09:15:37Z
dc.date.available2022-03-02T09:15:37Z
dc.date.issued2019
dc.identifier.citationRukundo, H. A. M., Taremwa, I. M., Muwanguzi, E., Ndyomubantu, M., Byarugaba, F., & Natukunda, B. (2019). Assessment of the quality of stored blood for transfusion at Mbarara Regional Referral Hospital, Southwestern Uganda. Journal of Blood Medicine, 10, 161.en_US
dc.identifier.urihttp://ir.must.ac.ug/xmlui/handle/123456789/1612
dc.description.abstractAim and objective: To assess the quality of blood stored for transfusion at Mbarara Regional Referral Hospital (MRRH) regarding bacterial contamination, malaria infection, and laboratory audit status. Materials and methods: Whole blood and packed red blood cells at MRRH were critically inspected for visual anomalies, and a portion of this blood was aseptically collected and analyzed for Plasmodium species and bacterial contamination using culture methods. For culture positive samples, drug susceptibility testing (DST) was done using the Kirby–Bauer disc diffusion method: An audit using Stepwise Laboratory quality Improvement Process towards Accreditation (SLIPTA) quality checklist was conducted. The obtained data were analyzed as frequencies and proportions at 95% confidence interval (CI), and significance levels of relatedness were set at p-values<0.05. Results: Of the 202 samples analyzed, 6 (3%) had bacteria while 3 (1.5%) had Plasmodium falciparum trophozoites. The bacterial isolates were Staphylococcus aureus (N=4, 66.7%); Corynebacterium spp (N=1, 16.7%) and Micrococcus spp (N=1, 16.7%). Staphylococcus aureus showed sensitivity to chloramphenicol, oxacillin, amikacin, and gentamycin. Thirty (14.9%) of these units had visually detectable anomalies, and the laboratory audit score was 53.8%. Conclusion: The quality of some blood stored for transfusion at MRRH was inadequate, and the laboratory quality standard based on SLIPTA was low. Based on this, it is crucial to always insist on aseptic measures at all stages (phlebotomy, processing, transporting, and blood storage) and consider more assessment of the donor risk to minimize transfusion transmitted malaria. It is plausible to standardize the hospital blood transfusion laboratory and revive hemovigilance by the hospital transfusion committee.en_US
dc.language.isoen_USen_US
dc.publisherJournal of Blood Medicineen_US
dc.subjectBacterial contaminationen_US
dc.subjectPlasmodium speciesen_US
dc.subjectBlood componentsen_US
dc.subjectLaboratory quality auditen_US
dc.subjectSLIPTAen_US
dc.titleAssessment of the quality of stored blood for transfusion at Mbarara Regional Referral Hospital, Southwestern Ugandaen_US
dc.typeArticleen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record